      Rated Current:
      Poles Number Type:
      Sale price $50.23Regular price $0.00
      Regular price $50.23

      Description

      SPECIFICATIONS

       

      Under voltage protection: 140V-210V(adjustable) (default: 160V)

      Over voltage protection: 230V-300V (adjustable) (default: 280V)

      Over current protection: 1A-80A (adjustable) (default: 20A)

      Reconnect time: 3s-300s (default: 5A)

      Brand Name: TOMZN

      Model Number: TOVPD1-60-EC

      Type: Voltage protector

      Smart Device: No

      Origin: China

      Customisable: Yes

      Choice: Yes

      Semi_Choice: Yes






      Functions:
      1.Over-voltage protection
      2.Under-voltage protection
      3.Over-current protection
      4.Automatic recovery
      5.Voltage display(voltage measurement)
      6.Current display (current measurement)
      7. Voltage calibration: Voltage +-10% adjustable. A13
      8. Restore factory settings: press the down button for more than 12s
      9.Fault inquiry: Press the UP button from more than 12S
      Product Parameters:  
      1.Model number:TOVPD1-60-EC
      2.Power supply:230VAC 50/60Hz
      3.Max.Loading power:1~40A  Adjustable(default:40A)
                                          1~63A  Adjustable(default:63A)
      4.Over-voltage protection value range:230V~300~OFF(default:270V)
        Over-voltage recovery voltage range:225V--295V(default:250V)
         Over-voltage protection action time:0.1s~30s(default value:0.5s)
      Over-voltage recovery delay time:1s~500s(default:30s)
      5.Under-voltage protection value range:140V--210V --OFF(default:170V)
        Under-voltage recovery voltage range:145V--215V (default:190V)
         Under-voltage protection action time:0.1s~30s(default:0.5s)
         Under-voltage recovery delay time:1s~500s(default:30s)
      6.Over-current adjustment range:1-40A (default:20A) 1-63A (default:40A)
         Over-current action range:0.1~30 second (default:0.5s)
      Over-current recovery delay time:1s~500s(default:30s)
      7.Power-on delay time:1s~500s(default:10s)
      9.Power consumption : <2W
      10.Electric machinery life : 100,000 times
      11.Installation:35mm DIN rail

      110V Version
      2.Power supply:110VAC 50/60Hz
      3.Max.Loading power:1~63A Adjustable(default:63A)
      4.Over-voltage protection value range:80V~300~OFF(default:145V)
      Over-voltage recovery voltage range:75V--295V(default:140V)
      Over-voltage protection action time:0.1s~30s(default value:0.5s)
      Over-voltage recovery delay time:1s~500s(default:30s)
      5.Under-voltage protection value range:80V--300V --OFF(default:90V)
      Under-voltage recovery voltage range:85V--305V (default:95V)
      Under-voltage protection action time:0.1s~30s(default:0.5s)
      Under-voltage recovery delay time:1s~500s(default:30s)
      6.Over-current adjustment range:1-63A (default:40A)
      Over-current action range:0.1~30 second (default:0.5s)
      Over-current recovery delay time:1s~500s(default:30s)
      7.Power-on delay time:1s~500s(default:10s)
      8.Power consumption : <2W
      9.Electric machinery life : 100,000 times
      10.Installation:35mm DIN rail

       

      A13 Voltage adjustable +-%9.5

      A14 Current limit times: 1-20 times (default off)

      Restore factory settings: Press the down button for more than 12s
      Fault inquiry: Press the UP button for more than 12S